Introducing preemptible compute: the same compute, half the price
Today we're announcing the public preview of preemptible compute for Together GPU Clusters, available on Kubernetes clusters in all regions. Preemptible nodes give teams a lower-cost way to run interruption-tolerant work — short experiments, inference bursts, batch jobs — on the.

- Preemptible nodes give teams a lower-cost way to run interruption-tolerant work — short experiments, inference bursts, batch jobs — on the same GPU infrastructure they already use, billed sub-hourly at a flat 50% of the on-demand rate.
- You can add preemptible capacity to a new or existing cluster starting today.
- Preemptible nodes are billed at a flat 50% of the on-demand rate.
Today we're announcing the public preview of preemptible compute for Together GPU Clusters, available on Kubernetes clusters in all regions. Preemptible nodes give teams a lower-cost way to run interruption-tolerant work — short experiments, inference bursts, batch jobs — on the same GPU infrastructure they already use, billed sub-hourly at a flat 50% of the on-demand rate. You can add preemptible capacity to a new or existing cluster starting today.
Preemptible compute adds a second compute type to Together GPU Clusters. Standard nodes are fulfilled synchronously and are never preempted. Preemptible nodes use the same NVIDIA accelerated compute, draw from un-used capacity, and can be reclaimed when that capacity is needed elsewhere.
Preemptible nodes are billed at a flat 50% of the on-demand rate. The rate remains fixed rather than moving with a spot market.
When a node is reclaimed, the cluster follows a five-minute drain (maximum 5 minutes) sequence:
T+0 — the node is cordoned, a TogetherPreempted Kubernetes event fires, and your pods receive SIGTERM.
T+0 to T+5:00 — your workload has up to five minutes ( terminationGracePeriodSeconds ) to checkpoint and exit.
The cluster retains its preemptible target after the node is removed and automatically refills toward that target as capacity becomes available. You do not need to request replacement capacity.
Billing is sub-hourly, with usage metered every one to two minutes. A node that runs for 12 minutes is billed for approximately 12 minutes.
Preemptible nodes are not a separate cluster type. They join your existing cluster, labeled together.ai/compute-class=preemptible , so interruptible workers run on discounted capacity while coordinators, login pods, and serving replicas stay on standard nodes.
The five-minute reclamation sequence makes recovery behavior the deciding factor. Work that can resume, retry, or requeue can use preemptible capacity while critical components should remain on standard nodes.
Short experiments. Ablations, config sweeps, quick fine-tunes, evals, distillation, and batch inference are good candidates when the work can resume from a checkpoint or retry after a worker disappears. Frameworks such as Ray Train and PyTorch Lightning resume from the latest checkpoint without intervention. As a reference point, a full weight model checkpoint for GLM5.3 Flash, 321B parameter model is roughly 3.5TB which would take between 22s to 4mins to write to a parallel filesystem even at degraded performance. Leaving headroom inside the five-minute drain window.
Temporary bursts. When batch or internal inference demand spikes, add cheaper preemptible nodes to absorb the burst and non-critical workloads instead of holding standard capacity sized for your peak or risking burst standard compute availability. Interrupted requests requeue; user-facing replicas remain on standard nodes.
The common thread: work that is chunked, checkpointed, or retryable. Multi-day runs without checkpointing and strict-SLO serving with no fallback are not a fit.
Together has a strong culture dogfooding , several internal research, dev/test and non-critical production workloads at Together are based on our preemptible compute based GPU clusters enabling us to leverage our spare capacity across product teams.
Treat preemptible nodes as ephemeral. There is no minimum node lifetime during the preview, so checkpoint frequently and plan for capacity to disappear at any time.
Keep critical components on standard nodes. Coordinators, login pods, and user-facing replicas belong to guaranteed capacity — use the compute-class label to enforce it.
Use the drain window. Set terminationGracePeriodSeconds to as much as 300 seconds, checkpoint when the pod receives SIGTERM, and exit before the node is removed.
Clusters require at least one standard node , and nodes can't be converted between compute types in place.
After the workload is prepared for preemption, setup has two parts: set the preemptible target and schedule eligible work onto the labeled nodes.
You can set the target when creating a cluster or on a cluster that is already running, using the Together Cloud console, CLI, or API. The API reports both the requested target, desired_preemptible_gpus , and the capacity currently live, allocated_preemptible_gpus . Because preemptible nodes draw from unused capacity, allocated capacity can remain below the desired target when capacity is tight.
Choose your standard node count, then add a preemptible target on top.
--name my-cluster --region us-central-2 --gpu-type RTX_6000_PCI \
--cluster-type KUBERNETES --num-gpus 8 --billing-type ON_DEMAND \
Scale up the preemptible target when you need additional worker capacity, then lower it when the work is complete. The cluster remains running throughout.
tg beta clusters update
Fig: Adding/Deleting Preemptible nodes to an existing cluster
Fig: Preemptible nodes follow the “gpu-preemptible-xxx” naming convention
Preemption notices are delivered as SIGTERM to the pod, as Kubernetes events ( reason=TogetherPreempted ), in the console's Event Timeline, and via the Together API's node_lifecycle_events — handling patterns are covered in the docs .
Preemptible compute is now in public preview on Kubernetes clusters. Slurm support, additional regions, and in-place conversion between compute types are planned next.
Sources
Related stories

Red Hat Shrinks Nemotron 3.5 Lightning's 30B Agent Model by Half With FP8
Red Hat AI released an FP8 quantized build of NVIDIA Nemotron 3.5 Lightning 30B A3B. Cuts GPU memory and disk by roughly 50% versus the BF16 reference weights.

Product updates: Sandbox Sidecars, new models, a refreshed dashboard, and more
August brought new model support, faster Function calls, and major improvements across Modal Sandboxes. Here are the highlights. 🤖 Day-zero support for Kimi K3, Qwen 3.8, GLM 5.3, and GLM 5.3 Flash Explore four frontier open-weight models now supported on Modal Auto Endpoints.

To Infinity and Beyond: ThunderKittens Now on NVIDIA Vera Rubin NVL72!
The kernels team at Together recently received access to the NVIDIA Vera Rubin NVL72 platform. We spent the past few days digging through the new ISA and poking the chip with micros.

This 27-year-old’s TikTok-like AI app makes playful, creative short videos from just a few words—it’s built for Gen Z - Fortune
Demi Guo, the 27-year-old founder of AI video company Pika, holds degrees in mathematics and computer science. But she’s also always had a creative streak, including writing poetry, and she loves showing off on social media with image and video tools.

Mitsuba Squeezes a 27B Vision Model Into 7.3 GB on One GPU
Subtopic Small Models · Vision Language · Quantization Mitsuba is a ternary 1.58-bit quantization of Qwen3.8-27B, shrunk to 7.3 GB for a single 16 GB GPU. Purpose-built for ComfyUI: image to prompt generation for Stable Diffusion, Krea, and video pipelines.

AI Weekly Issue #528: What are companies building with AI? An Applied AI Deep Dive
We went looking for what companies are actually building with AI. The answer was not more chatbots. It was drones carrying diagnostic samples, driverless Frito-Lay trucks, AI-guided flight paths, repair copilots, and rugged GPU laptops in Ukraine.